IRG 2000 |
|
|
Pulse voltage |
10 – 60 V |
|
Pulse width |
40 ns – 10 μs |
|
Voltage-proof up to |
400 V, 50/60 Hz |
|
Output impedance |
10 – 250 Ohm |
|
Input signal gain |
0 – 60 dB |
|
Measurement range |
0 – 65 km (at v/2 = 80 m/μs) |
|
Accuracy |
0.2 % |
|
Sampling rate |
200 MHz (5 ns) |
|
Resolution |
0.4 m (at v/2 = 80 m/μs) |
|
Velocity of propagation (v/2), adjustable |
50 – 150 m/μs |
|
Storage capacity |
100 measurements |
|
Display |
6” LCD, screen resolution 320 x 240 pixels |
|
User interface languages |
English, French, German, Dutch, Italian, |
|
Surge voltage generator |
|
|
Surge voltage ranges |
0 – 8 kV, 0 – 16 kV |
|
Surge energy |
1,024 J |
|
Surge sequence |
1 – 20 pulses/min, single surge |
|
DC voltage |
0 – 16 kV |
|
Display |
LCD with background lighting, screen resolution 160 x 80 pixels |
|
User interface languages |
English, German, Polish, Portuguese, Russian |
|
System |
|
|
Power supply |
100 - 240 V, 50/60 Hz |
|
Max. power consumption |
1,500 VA |
|
Ambient temperature (operational) |
-10 to +50 °C |
|
Storage temperature |
-20 to +60 °C |
|
Relative humidity |
90 %, non-condensing |
|
Degree of protection |
IP42 |
|
Dimensions (W x H x D) |
approx. 680 x 1,160 x 670 mm (incl. carry handle and wheels) |
|
Weight |
approx. 90 kg |