High AC current output |
||||
|
Current output, A |
Output power, VA |
Load time, s |
Recovery time, min |
|
|
100 |
600 |
steady |
- |
|
|
150 |
8000 |
15 min |
30 |
|
|
200 |
1000 |
4 min |
15 |
|
|
400 |
1600 |
15 |
5 |
|
|
600 |
2000 |
5 |
3 |
|
|
800 |
2000 |
1 |
2 |
|
|
Low AC current output (High power range) |
||||
|
Range, A |
Current output, A |
Output power, VA |
Max test duration, s |
Recovery time, min |
|
40 |
12 |
300 |
steady |
- |
|
18 |
|
15 min |
30 |
|
|
24 |
|
4 min |
15 |
|
|
36 |
800 |
15 |
5 |
|
|
48 |
|
5 |
3 |
|
|
60 |
1000 |
1 |
2 |
|
|
10 |
5 |
400 |
steady |
- |
|
7.5 |
|
15 min |
30 |
|
|
10 |
800 |
60 |
15 |
|
|
15 |
|
30 |
10 |
|
|
20 |
1000 |
15 |
5 |
|
|
Low AC current output (Low power range) |
||||
|
Range, A |
Current output, A |
Output power, VA |
Max test duration, s |
Recovery time, min |
|
40 |
12 |
60 |
steady |
- |
|
17 |
10 min |
30 |
||
|
23 |
60 |
10 |
||
|
36 |
1 |
2 |
||
|
10 |
5 |
60 |
steady |
- |
|
6 |
10 min |
45 |
||
|
7 |
60 |
2 |
||
|
10 |
1.5 |
2 |
||
|
Low DC current output |
||||
|
Current output, A |
Load resistance, Ohm |
Output power, VA |
Max test duration, min |
|
|
6 |
0 |
0 |
steady |
|
|
3 |
2 |
18 |
steady |
|
|
1 |
8 |
8 |
steady |
|
|
High AC voltage output (3000 V version) |
||||
|
Voltage output, V |
Current output, A |
Output power, VA |
Max test duration, min |
|
|
3000 |
0.2 |
600 |
steady |
|
|
2500 |
0.6 |
1500 |
1 |
|
|
High AC voltage output (1200 V version) |
||||
|
Voltage output, V |
Current output, A |
Output power, VA |
Max test duration, min |
|
|
1200 |
0.5 |
600 |
steady |
|
|
1200 |
1.5 |
1800 |
1 |
|
|
Low AC voltage output |
||||
|
Voltage output, V |
Current output, A |
Output power, VA |
Max test duration, min |
|
|
250 |
0.5 |
125 |
steady |
|
|
220 |
1.15 |
250 |
3 |
|
|
Timer |
||||
|
Inputs |
free of voltage or with voltage |
|||
|
Programmable voltage threshold |
24 V or 80 V |
|||
|
Metering range, in seconds |
from 0 to 9.999 s; 10.00 to 99.99 s; 100.0 to 999.9 s; 1000 to 9999 s |
|||
|
Metering range, in cycles |
from 0 to 1000.0 cycles; from 1000 to 500,000 cycles |
|||
|
Counting mode |
this mode is foreseen for the test of energy meters |
|||
|
Maximum input frequency |
10 kHz |
|||
|
Auxiliary binary output |
||||
|
Contact range |
5 A; 250 V AC; 120 V DC |
|||
|
Measuring section |
||||
|
Phase angle measurement accuracy |
1° |
|||
|
Frequency accuracy |
1 mHz |
|||
|
Current measurements |
Two inputs: 20 mA AC or DC or 10 A AC |
|||
|
Voltage measurement |
Two inputs: 10 V or 600 V, AC or DC |
|||
|
Ratio |
0.1 to 9999; |
|||
|
Resistance |
Up to 250 Ohm; |
|||
|
Other characteristics |
||||
|
Display |
FSTN, 240x128 pixels (135x80 mm) |
|||
|
Local memory |
up to 500 results |
|||
|
Interface |
RS232 |
|||
|
Mains supply |
230 V ± 10%; 50-60 Hz, or |
|||
|
Dimensions |
455 (W) x 325 (D) x 290 (H) mm |
|||
|
Weight |
31 kg |
|||