iCT1 Current and Voltage transformer test set

iCT1 is a fully automatic Current and Voltage transformer test set, especially designed for testing CTs, VTs and Combined Transformers. He`s grants a faster testing, thanks to its 5-TAP switchbox which allows to connect directly up to 5 taps, in this way the connection of the device is made only one time and without the need of any further manual operation.

Manufactory: ISA - ALTANOVA GROUP (Italy).

Features
  • Designed to test Current, Voltage and Combined transformers
  • Time saving testing: only 1 set up connection to perform all the tests
  • Main tests performed: Ratio & Phase Error, Excitation, Resistance, Accuracy, Burden
  • 5-TAP integrated switchbox describing the behavior of the CT
  • Able to test CT with saturation voltage up to 2kV and till 30kV applying DC indirect method
  • Integrated demagnetizer
  • CT Explorer function: able to find the nameplate data of the CT
  • Compact and lightweight
  • Patented technology

High AC voltage

The high AC voltage output up to 2kV is coming from a transformer that provides to insulate the outputs from the power supply.

Range

Resolution

Typical Error
[<%rdg] [<%rg]

Guaranteed Error
[±%rdg] [±%rg]

2100 V
200 V
20 V
2 V

100 mV
10 mV
1 mV
100 μV

< 0,02 % < 0,02 %

± 0,05 % ± 0,05 %

Low AC current

The output current can be manually adjusted using the front panel controls

Range

Resolution

Typical Error
[<%rdg] [<%rg]

Guaranteed Error
[±%rdg] [±%rg]

10 A
1 A
0,1 A

1 mA
0,1 mA
0,01 mA

< 0,025 % < 0,025 %

± 0,05 % ± 0,1 %
± 0,10 % ± 0,05 %
± 0,15 % ± 0,05 %

Low DC current

Output current can be manually adjusted using the front panel controls

Range

Resolution

Typical Error
[<%rdg] [<%rg]

Guaranteed Error
[±%rdg] [±%rg]

15 A
1,5 A
0,15 A

1 mA
0,1 mA
0,01 mA

< 0,025 % < 0,025 %

± 0,05 % ± 0,05 %

Low AC voltage

Range

Resolution

Typical Error
[<%rdg] [<%rg]

Guaranteed Error
[±%rdg] [±%rg]

300 V
30 V
3 V
300 mV

15 mV
1,5 mV
0,15 mV
0,015 mV

< 0,02 % < 0,02 %

± 0,05 % ± 0,05 %

Low voltage for excitation curve DC method

Range

Resolution

Typical Error
[<%rdg] [<%rg]

Guaranteed Error
[±%rdg] [±%rg]

200 V
20 V
2 V
200 mV

10 mV
1 mV
100 μV
10 μV

< 0,025 % < 0,025 %

± 0,05 % ± 0,05 %

20 mV

1 μV

< 0,05 % < 0,05 %

± 0,01 % ± 0,01 %

Output frequency

Range

Resolution

Accuracy

15Hz – 400Hz

10mHz

< 100 ppM; output voltage > 200 V

Ratio test (accuracy for CT ratio measurements)

Range

Typical accuracy

Maximum accuracy

0,8 ÷ 2000
2000 ÷ 5000
5000 ÷ 20000

± 0,02 %
± 0,03 %
± 0,05 %

± 0,05 %
± 0,10 %
± 0,20 %

Ratio test (accuracy for VT ratio measurements)

Range

Typical accuracy

Maximum accuracy

1 ÷ 400
400 ÷ 1000
1000 ÷ 2500

± 0,03 %
± 0,05 %
± 0,05 %

± 0,2 %
± 0,3 %
± 0,5 %

Phase Angle

Range

Resolution

Accuracy (cosφ 0.8 - 1)

0° ÷ 360.0°

0.01° (< 1 minute)

< 4 minutes (maximum) For amplitudes more tha

Standard accessories:

  • iCT1 Standard test set with cable kit or
  • iCT1 Advance test set with cable Kit;
  • iCt1 Software licence.

Optional accessories:

  • HVB4000 4kV High voltage booster for VT test;
  • Transit case;
  • Long cables test kit 18m for EHV CT.