Logo_ESKAN.png
UA EN

CMM-10 Multimeter

CMM-10 is one of the best solutions for residential and commercial electricians. Additional temperature measurement means that the device can be used by heating and air-conditioning technicians.

Manufacturer: SONEL S.A. (Poland).
Features
  • Autoranging/manual range selection
  • DATA HOLD function, for holding measured values
  • REL function, which allows you to make measurements relative to a stored reference value
  • Continuity test with acoustic signalling (beeper)
  • AUTO-OFF function
  • Display 3 7/8 digits (5000 max)

AC voltage measurement

Range

Resolution         

Accuracy

400,0 mV  

0,1 mV

±(1,5% m.v. + 70 digits)        

4,000 V

0,001 V

±(1,2% m.v. + 3 digits)

40,00 V

0,01 V

±(1,5% m.v. + 3 digits)

400,0 V

0,1 V

600 V

1 V

±(2,0% m.v. + 4 digits)

DC voltage measurement

Range

Resolution

Accuracy

400,0 mV

0,1 mV

±(0,5% m.v. + 2 digits)

4,000 V

0,001 V

±(1,2% m.v. + 2 digits)

40,00 V

0,01 V

±(1,2% m.v. + 2 digits)

400,0 V

0,1 V

600 V

1 V

±(1,5% m.v. + 2 digits)

AC current measurement

Range

Resolution

Accuracy

400,0 μA

0,1 μA

±(1,5% m.v. + 5 digits)

4 000 μA

1 μA

±(1,8% m.v. + 5 digits)

40,00 mA

0,01 mA

400,0 mA

0,1 mA

4,000 A

0,001 A

±(3,0% m.v. + 7 digitgs)

10,00 A

0,01 A

DC current measurement

Range

Resolution

Accuracy

400,0 μA

0,1 μA

±(1,0% m.v. + 3 digits)

4 000 μA

1 μA

±(1,5% m.v. + 3 digits)

40,00 mA

0,01 mA

400,0 mA

0,1 mA

4,000 A

0,001 A

±(2,5% m.v. + 5 digits)

10,00 A

0,01 A

Resistance measurement

Range

Resolution

Accuracy

400,0 Ω

0,1 Ω

±(1,2% m.v. + 4 digits)

4,000 kΩ

0,001 kΩ

±(1,0% m.v. + 2 digits)

40,00 kΩ

0,01 kΩ

±(1,2% m.v. + 2 digits)

400,0 kΩ

0,1 kΩ

4,000 MΩ

0,001 MΩ

40,00 MΩ

0,01 MΩ

±(2,0% m.v. + 3 digits)

Capacitance measurement

Range

Resolution

Accuracy

40,00 nF

0,01 nF

±(5,0% m.v. + 7 digits)

400,0 nF

0,1 nF

±(3,0% m.v. + 5 digits)

4,000 μF

0,001 μF

40,00 μF

0,01 μF

100,0 μF

0,1 μF

±(5,0% m.v. + 5 digits)

Temperature measurement

Range

Resolution

Accuracy

-20°C...+760°C       

1°C

±(3% m.v. + 5°C, 9°F)

-4°F...+1400°F

1°F

Frequency measurement

Range

Resolution

Accuracy

5,000 Hz

0,001 Hz

±(1,5% m.v. + 5 digits)

50,00 Hz

0,01 Hz

500,0 Hz

0,1 Hz

±(1,2% m.v. + 3 digits)

5,000 kHz

0,001 kHz

50,00 kHz

0,01 kHz

500,0 kHz

0,1 kHz

5,000 MHz

0,001 MHz

±(1,5% m.v. + 4 digits)

10,00 MHz

0,01 MHz


Standard accessories:

  • CMM‐10
  • Test leads for clamp- and multimeters (set)
  • Probe (K-type)
  • Adapter
  • 6LR61 9 V battery
  • User manual

Optional accessories:

  • Set of test leads for CMM (CAT IV, S)
  • Set of test leads for CMM (CAT IV, M)
  • Probe (K-type, bayonet)
  • Probe (K-type, metal)
  • Crocodile clip mini, 1 kV 10 A (set)
  • S1 carrying case