MIC-10 Insulation resistance meter

MIC-10 is an insulation resistance meter, which may be very useful for various electrical works (even the simplest), in locations with Low Voltage power supply, including: electrical systems in single- and multi-family buildings as well as in public buildings and in small workshops or factories. With its test voltage settings of 50 V, 100 V or 250 V the device is perfect for quick checking of the insulation condition in telecommunications systems and control cables.   

Manufacturer: SONEL S.A. (Poland).

Description

Test voltage settings of 500 V or 1000 V perfectly match the requirements for assessing the protection of power supply lines but also of floors and walls - PRS-1 probe (optional accessory) is very useful for this purpose.

With MIC-10 meter you can check whether an object is under voltage (measuring range up to 600 V), both in overhead and cable networks (measuring category of the device: CAT IV 600 V). You can verify the continuity of cables, e.g. PE connections and equipotential bonding - using the current of at least 200 mA, according to EN 61557-4. You can check the capacity of the start-up capacitors in household appliances and drives of any type (measuring range up to 10 μF).

This makes MIC-10 meter an essential tool for every service technician.
Features
  • Measurement of insulation resistance up to 10 GΩ thanks to max 1000 V measurement voltage
  • Designed for harsh environmental conditions - IP67 ingress protection
  • Allows for testing electrical continuity - Rcont 200 mA function
  • Checking start capacitors in motors thanks to capacity measurement function
  • Continuous reading of measured insulation resistance
  • Automatic discharge of the measured object’s capacitance upon completion of insulation resistance measurement
  • Sound signalling of five-second time intervals, facilitating capture of time characteristics
  • Readings of actual measurement voltage during measurement
  • Protection against measurement of live objects
  • Three-lead measurement
  • Capacitance measurement during measurement of Riso
  • Low-voltage measurement of circuit continuity and resistance
  • Continuity test of protective conductors and equipotential bonding with current ≥200 mA flowing in two directions in compliance with EN 61557-4
  • Measurement of direct and alternating voltages within the range of 0…600 V

Insulation resistance measurement

Range

Resolution   

Accuracy

0.0…999.9 kΩ

0.1 kΩ

± (3% m.v. + 8 digits)

1.000…9.999 MΩ

0.001 MΩ

10.00…99.99 MΩ

0.01 MΩ

100.0…250.0 MΩ (for Un = 50 V)
100.0…500.0 MΩ (for Un = 100 V)
100.0…999.9 MΩ (for Un ≥ 250 V)

0.1 MΩ

1.000…2.000 GΩ (for Un = 250 V)

0.001 GΩ

1.000…5.000 GΩ (for Un = 500 V)

0.001 GΩ

±(4% m.v. + 6 digits)

1.000…9.999 GΩ (for Un = 1000 V)

10.00 GΩ (for Un = 1000 V)

0.01 GΩ

Low-voltage measurement of continuity of circuit and resistance

Range

Resolution

Accuracy

0.00…19.99 Ω

0.01 Ω

±(2% m.v. + 3 digits)

20.0…199.9 Ω

0.1 Ω

200…1999 MΩ

1 Ω

±(4% m.v. + 3 digits)

DC and AC voltage measurement

Range

Resolution

Accuracy

0…299.9 V

0.1 V

±(2% m.v. + 6 digits)

300…600 V

1 V

±(2% m.v. + 2 digits)

Capacitance measurement

Range

Resolution

Accuracy

1…999 nF

1 nF

±(5% m.v. + 10 digits) ±(5% m.v. + 10 digits)

1.00…9.99 μF

0.01 μF

Low-current resistance measurement

Range

Resolution

Accuracy

0.00…199.9 Ω

0.1 Ω

±(3% m.v. + 3 digits)

200…1999 MΩ

1 Ω

Technical specification

Type of insulation

double, according to EN 61010-1 and EN 61557

Measurement category

IV 600 V (III 1000 V) according to EN 61010-1

Degree of housing protection acc. To en 60529   

IP67

Power supply of the meter

4 x AA alkaline batteries or rechargeable batteries

Dimensions

200 x 100 x 60 mm

Meter weight

approx. 0.6 kg

Operating temperature

-10°C…+50°C

Display

LCD segment

Standard accessories:

  • MIC-10
  • Test probe with banana socket; 1 kV; black
  • Test probe with banana socket; 1 kV; red
  • Black “crocodile” clip 1 kV 20 A
  • Test lead with banana plugs; 1 kV; 1.2 m; black
  • Test lead with banana plugs; 1 kV; 1.2 m; red
  • M-6 carrying case
  • Mmeter strap (type M-1)
  • M-1 housing holder - hanger
  • User manual

Optional accessories:

  • Ppin probe, blue 1 kV (banana socket)
  • Rred “crocodile” clip 1 kV 20 A
  • Blue “crocodile” clip 1 kV 20 A
  • Test lead 5 m, black, 1 kV (banana plugs, shielded)
  • Test lead 5 m, red, 1 kV (banana plugs)
  • Test lead 5 m, blue, 1 kV (banana plugs)
  • Shielded test lead with banana plugs; 1 kV; 1.2 m; black
  • CS-1 cable simulator
  • Test lead with banana plugs; 1 kV; 1.2 m; blue
  • AGT-16P threephase socket adapter 16 A
  • AGT-32P threephase socket adapter 32 A
  • AGT-63P threephase socket adapter 63 A
  • AGT-16C threephase socket adapter 16 A (PEN)
  • AGT-32C threephase socket adapter 32 A (PEN)
  • PRS-1 resistance test probe
  • AGT-16T industrial socket adapter 16 A
  • AGT-32T industrial socket adapter 32 A
Back to the list