Output voltage |
|
|
Frequency range |
0.01 – 0.1 Hz |
|
VLF truesinus® |
1 – 26.1 kVrms |
|
VLF square wave voltage |
1 – 34 kV |
|
DC voltage |
±1 – 34 kV |
|
Resolution |
0.1 kV |
|
Accuracy |
1 % |
|
Load range (VLF testing) |
1 nF – 8 μF |
|
Output current |
|
|
Measurement range |
0 – 14 mA |
|
Resolution |
1 μA |
|
Accuracy |
1 % |
|
Max. capacitive load |
0.5 μF at 0.1 Hz / 24 kVrms
/ 34 kVpeak |
|
Dissipation factor measurement (frida TD) |
|
|
VLF truesinus® |
1 – 26.1 kVrms |
|
Load range |
10 nF - 8 μF |
|
Resolution |
1 x 10-6 |
|
Accuracy |
1 x 10-4 |
|
Measurement range |
1 x 10-4 – 21,000 x 10-3 |
|
tan δ measuring frequency |
0.1 Hz |
|
Automatic detection and compensation of leakage currents |
With VSE box (optional) |
|
General |
|
|
Input voltage |
100 – 260 V, 50/60 Hz |
|
Power consumption |
max. 300 VA |
|
Reverse voltage protected |
up to 13 kV |
|
Degree of protection |
IP54 (in closed state) |
|
Data interface |
USB 2.0 |
|
Dimensions (W x H x D) |
438 x 456 x 220 mm |
|
Weight (incl. HV connection cable) |
Approx. 22 kg |
|
Ambient temperature (operational) |
-10 to +50°C |
|
Storage temperature |
-20 to +60°C |
|
Safety and EMC |
CE-compliant in accordance with |
|
User interface available in 13 languages |
Czech, Chinese (CN), Chinese (TW), Dutch, |