SSG 500 Surge voltage generator
The SSG 500 is used to generate surge and DC voltage and can be used for the pre-location and pin-pointing of cable faults in buried power cables, in particular low voltage cables.
Manufactory: BAUR (Austria).
Description
The SSG 500 surge voltage generator is arranged in a 19'' housing. Maximum safety is achieved with the electrical safety control unit, the automatic discharge unit, the fully enclosed design and separate protective and operational earthing.
The device generates surge voltages of 4 / 8 / 16 kV or 3 / 6 / 12 kV. In surge mode, the charge of the HV capacitors can be discharged to the faulty cable manually or automatically, as required, at a rate of 10 or 20 surges/min. When the device is switched off, the HV output is automatically discharged.
Features
- 6 selectable surge voltages up to 16 kV
- High output current up to DC 480 mA
- Automatic surge mode or manual triggering of voltage surges
- Rapid surge sequence up to 20 surges/min
- Surge energy up to 512 J (can be switched to 56 %)
- Electromagnetically actuated surge switch
- Voltmeter with 3 display ranges
- Safety control unit according to DIN EN 50191
- Integrated automatic discharge unit
- Overcurrent protection switch with thermal and magnetic triggering
- Connection option for external emergency off unit with signal lamps
|
Output voltage
|
|
Max. DC voltage
|
16 kV
|
|
Surge voltage
|
4 / 8 / 16 kV
3 / 6 / 12 kV (switchable to 56 % of the surge energy)
|
|
Surge energy
|
512 J @ 4 / 8 / 16 kV
288 J @ 3 / 6 / 12 kV
|
|
Max. output current (in DC mode)
|
Depending upon the position of the step selector switch:
DC 480 mA @ 4 kV position
DC 240 mA @ 8 kV position
DC 120 mA @ 16 kV position
|
|
Surge sequence
|
10 or 20 pulses/min
|
|
Display range of thevoltmeter
|
0 – 4 kV
0 – 8 kV
0 – 16 kV
|
|
Accuracy of the voltmeter
|
1.5 %
|
|
General
|
|
Power supply
|
220 – 230 V, 50/60 Hz
|
|
Power supply (option)
|
110 – 120 V, 50/60 Hz (with external auto transformer)
240 V, 50/60 Hz (with conversion kit for mains supply)
|
|
Max. power consumption
|
1,500 VA (in the event of short circuit)
|
|
Ambient temperature (operational)
|
-10 to +50°C
|
|
Storage temperature
|
-20 to +60°C
|
|
Dimensions (W x H x D)
|
Approx. 500 x 290 390 mm
|
|
Weight
|
Approx. 48 kg
|
|
Safety and EMC
|
CE-compliant in accordance with
Low Voltage Directive (2014/35/EU),
EMC Directive (2014/30/EU),
EN 60068-2-ff Environmental testing
|
Standard accessories:
- SSG 500
- Earth cable, 3 m, with earth terminal
- Mains supply cord, 2.5 m
- User manual
Optional accessories:
- Hinged stand for 19” devices, height 5 RU (222 mm)
- Discharge and earth rod GDR 40-250
- Conversion kit for 240 V mains supply
- External auto transformer, 110/230 V; 1.5 kVA
- External emergency off unit with signal lamps, incl. connection cable, 25 m, on hand drum
- External emergency off unit with signal lamps, incl. connection cable, 50 m, on hand drum
- SA 32 SIM/MIM coupling unit
- SK 1D inductive coupling for ICM